The ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.
2 second Max. At 115Vac input and output Max. Load.
40mS Max. At 115Vac input and output Max. Load.
5mS Min. At 115Vac input and output Max. Load.
80%Min.At 100Vac input and output Max. Load.
83%Min.At 240Vac input and output Max. Load.
15%Max.When power supply at turn on or turn off.
4、保护功能(PROTECTION REQUIREMENT):
4.1短路电路保护:
Short Circuit Protection:
该电源供给器在短路解除时,能正常工作恢复。
The power supply will be auto recovered when short circuit faults remove.
4.2过流保护(Over current Protection):过流故障排除后,电源将自动恢复正常工作。
The power supply will be auto recovered when over current faults remove.
4.3过压保护(Over Voltage Protection)
当输出电压超过额定电压时,电源将保护,故障排除后能恢复正常工作。
The power supply will not be auto recovered when faults remove.
5、环境要求(ENVIRONMENTAL REQUIREMET):
5.1工作温度(Operating Temperature):
0℃~40℃,满载,正常工作(Full load Normal operation)。
0℃to40℃,Full load Normal operation.
5.2储存温度(Storage Temperature):-20℃to40℃,带外壳(With package).
5.3工作湿度(Relative Humidity):
5%(0℃)~90%(40℃),72小时,满载,正常工作
5%(0℃)~90%(40℃)RH,72Hrs,Full load Normal operating.
5.4振动(Vibration):
1、测试标准:国际电工电子委员会 Operating: IEC 721-3-3 3M3
5~9Hz,A=1.5mm 加速度(9~200Hz,Acceleration 5m/s2) 2、运输(Transportation): IEC 721-3-2 2M2
5-9Hz,A=3.5mm
9~200Hz,加速度Acceleration=5m/S2
200~500HZ,加速度Acceleration=15m/S2
3、轴向振动(Axes,10 cycles per axis).
在测试过程中不能出现永久性的损坏。
No permanent damage may occur during testing.
在电源开启和关闭后,样机能够恢复到最初条件。
The product has to restors its original situation after power off/on.)
5.5跌落试验(Dropping)(Packed):
一个角,三个棱, 六个面。
1 corner,3 edges, and 6 surfaces
高度76m Height:76cm
6、安全及EMC要求(SAFETY AND EMC REQUIREMENT):
6.1安全:符合UL标准
6.2高压(DIELECTRIC STRENGTH)(H-Pot):
()Primary to secondary),3000Vac/5mA/60s.
7、结构参数(MECHANICAL REQUIREMENT):
产品尺寸:170*72*41.5MM
DC线:L=1.5M DC头:5.5*2.5*11MM
plastic shell dimension::17*7*4cm
white paper box dimension:20*9*8cm
weight:0.64kg