Protection |
Overload Protection |
105%-150%Rated power, automatic recover |
Output Over-voltage protection |
110%-120%Rated voltage |
Output Short- Circuit Protection |
Output short ciruit when the power will not damage for a long time, short circuit after removing the power can be restored to normal work. |
Over-Temperature Protection |
/ |
Other Function |
Environment
|
Working temperature & humidity |
-20~+40℃@100%LOAD, +60℃@60%LOAD, 20%~90%RH |
Storage temperature & humidity |
-20~+85℃ , 10%~95%RH |
Heating |
Natural cooling |
Safety & EMC |
Safety Standard |
UL 60950 Standard |
Withstand Voltage |
I/P-O/P: 3KV AC, 10mA,60S |
Insulation Resistance |
I/P-O/P: 500VAC 100MΩ |
Reliability |
MTBF |
According to the MIL-HDBK-217F standards, full load, 25℃, MTBF 30000 hours |
Input output pin function of RJ-45 port |
RJ-45 Input (Data Only) |
RJ-45 Output (Data & Power) |
Pin |
Symbol |
Description |
Symbol |
Description |
1 |
RX+ |
Data Receive(+) |
RX+ |
Data Receive(+) |
2 |
RX- |
Data Receive(-) |
RX- |
Data Receive(-) |
3 |
TX+ |
Data Transmit(+) |
TX+ |
Data Transmit(+) |
4 |
BI_D3+ |
Bi-directional Data+ |
BI_D3+ |
DC power(+) & Bi-directional Data+ |
5 |
BI_D3- |
Bi-directional Data- |
BI_D3- |
DC power(+) & Bi-directional Data- |
6 |
TX- |
Data Transmit(-) |
TX- |
Receive Data- |
7 |
BI_D4+ |
Bi-directional Data+ |
BI_D4+ |
DC power(-) & Bi-directional Data+ |
8 |
BI_D4- |
Bi-directional Data- |
BI_D4- |
DC power(-) & Bi-directional Data- |
Dimensions&
Weight |
Weight |
170±20g |
Dimensions |
83mm*55mm*47mm |
Remark |
1, All the parameter values in 220 vac input, rated load, environmental temperature 25℃, 70% humidity conditions is measured. 2, Precision including setting error precision, the line regulation, load regulation, etc. 3,Ripple test, through the output lines to connect the power and load,load0.1uF and 47uF capacitance in parallel, to 20M bandwidth oscilloscope measured at the load end. 4, Line regulation: under the rated, the measured input voltage changes from low to high. 5, Load regulation: measured output load from 0 to 100% measured load change. |